Current site: Peikko Group Global (English). Do you want to change country or language?
Peikko Group Global (English)
The seismic column foundation solution is formed by standard column shoes and anchor bolts working together as a structural connection system.
Guidelines for designing column-to-foundation connections for seismic performance are provided in the technical manuals of Peikko column shoes. Designers should refer to the relevant column shoe documentation to apply the overstrength design approach correctly and to ensure compliance with applicable seismic design standards.

Background, design principles, and test results demonstrating the seismic performance of Peikko’s column-to-foundation connections. The paper presents the overstrength design approach using standard components and their performance in full-scale cyclic testing.